DPS Series UPS, Three Phase, 300/400/500/600/800/1000/1200 kVA

DPS Series UPS, Three Phase, 300/400/500/600/800/1000/1200 kVA
کالای فیزیکی

DPS Series UPS, Three Phase, 300/400/500/600/800/1000/1200 kVA

ناموجود
اضافه به سبد خرید

he Next Generation UPS Answering the Demand of Large Data Centers and Colocations

Delta's superior Ultron DPS series 300-1200 kVA UPS supports unity output power factor to deliver up to 10 MW power capacity to meet the demands for large data centers and colocations that require higher power capacity. The Ultron DPS series guarantees the highest level of system reliability and resiliency by supporting self-detection of key components with pre-warning function, multilayered redundancy design, and complete power rating coverage. Moreover, the DPS series supports advanced manageability. Key environment parameters, and event analysis can all be monitored via local 10” LCD monitor and remotely. Along with optional battery management software, the DPS series enables users to achieve predictive maintenance and minimize system downtime, while lowering the total cost of ownership (TCO).

Applications:

Model
DPS-300K / DPS-400K / DPS-500K / DPS-600K

DPS-800K / DPS-1000K / DPS-1200K

Power Rating

● DPS-300K
300 kVA / 300 kW

● DPS-400K
400 kVA / 400 kW

● DPS-500K
500 kVA / 500 kW

● DPS-600K
600 kVA / 600 kW

● DPS-800K
800 kVA / 800 kW

● DPS-1000K
1000 kVA / 1000 kW

● DPS-1200K
1200 kVA / 1200 kW

Input

Nominal Voltage
220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G)

Voltage Range
176/304~276/478 Vac (full load)

Current Harmonic Distortion
< 3% (with Full Linear Load)

< 5% (with Full Non-linear Load)

Power Factor
> 0.99

Frequency Range
40~70 Hz

Output

Voltage
220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G)

Voltage Harmonic Distortion
< 1.5% (Linear Load)

< 5% (Non-linear Load)

Voltage Regulation
± 1% (static), ± 5% (dynamic)

Output Power Factor
1

Frequency
50/60 Hz (Auto-Selectable)

Overload Capability
≤ 125%: 10 min

≤ 150%: 1 min

>150%: 1 sec

Display
10” Color Touch Panel

Interface

Standard
RS232, Parallel port, USB, Modbus RS485, Input dry contact, Output dry contact, SNMP card inbuilt in touch screen

Optional
Relay I/O card, Battery cabinet temperature sensor cable

Conformance
Safety: CE

Efficiency

AC-AC
Up to 96.5%

ECO Mode
99%

Battery

Type
VRLA, LiB

Charge Current

● DPS-300K
90 A

● DPS-400K
120 A

● DPS-500K
150 A

● DPS-600K
180 A

● DPS-800K
240 A

● DPS-1000K
300 A

● DPS-1200K
360 A

Battery Quantity
30~46 pcs

Environment

Operating Temperature
0~40℃

Relative Humidity
0~95% (non-condensing)

Audible Noise
< 80 dB

IP Protection
IP20

Others

Parallel Redundancy and Expansion
Maximum 8 units

Emergency Power Off
Remote and local

Physical

Dimensions (W x D x H)

● DPS-300K
600* x 900 x 2000 mm

● DPS-400K/500K/600K
1200* x 900 x 2000 mm

● DPS-800K
1800 x 900 x 2000 mm

● DPS-1000K/1200K
2450 x 900 x 2000 mm

Weight

● DPS-300K
515 kg

● DPS-400K
700 kg

● DPS-500K
811 kg

● DPS-600K
970 kg

● DPS-800K
1270 kg

● DPS-1000K
1850 kg

● DPS-1200K
2000 kg